Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 68 of 75
4.22.7
A battery shall be so located and mounted that the terminals of
cells will be prevented from coming in contact with the terminals
of adjacent cells, or with the metal parts of the battery
compartment, as the result of shifting of the battery.
N/A
4.22.8
.Vented wet cell batteries may be integral with the PCE
provided that all the following conditions are met: (a) the
enclosure or compartment housing the batteries is vented; (b)
arcing parts such as the contacts of switches, circuit breakers,
and relays are not located in the battery compartment; and (c)
the battery compartment does not vent into compartments with
enclosed spaces that contain arcing parts.
Note: The requirements of Clause do not apply to sealed-cell or
valve-regulated batteries.
N/A
4.22.9
If vented wet cell batteries are housed in an enclosure or
compartment, the ventilation shall provide four changes of air
per hour and the PCE shall be marked in accordance with
Clause 5.18.
N/A
4.22.10
A metal case or container of a battery, such as an alkaline
battery, shall be insulated or spaced away so as not to contact
uninsulated live parts of the PCE if such contact may result in a
short circuit.
N/A
4.22.11
An enclosure or compartment housing batteries having metal
containers or cases that are conductively connected to a
battery electrode shall be such that the batteries are insulated
or spaced from each other, or otherwise physically arranged, to
prevent short-circuiting of part or all of the battery supply after
installation in the PCE.
N/A
4.22.12
A battery that requires the addition of water shall have a means
to determine the fluid level.
N/A
4.22.13
If transformer isolation is not provided between the ac input
circuit of the PCE and the battery circuit
(a) the batteries shall be located in a compartment that cannot
be accessed without the use of a tool;
(b) the battery terminals shall be guarded to reduce the
likelihood of unintentional contact with the battery terminals by
service personnel; and
(c) the marking specified in Clause 5.21 shall appear adjacent
to the batteries where visible before removing the guard; the
warning shall not be located on the guard.
N/A
4.22.14
If the battery voltage under any normal condition including
charging exceeds 42.4 V, a battery cabinet for external
connection to a PCE shall
(a) be bonded to groundor to the frame of the bonded PCE or
be double-insulated in accordance with CSA C22.2 No.0.1;
(b) if cord-connected, have all external plug and receptacle
connectors
(i) provided with a guard to prevent accidental contact with
bare live parts of such connectors including any not required for
operation of the PCE, unless a tool is required for their
separation; and
(ii) marked in accordance with Clause 5.25; and
(c) if for nonpermanent connection, have interconnecting wiring
not more than 2 m long, if unjacketed conductors are used
N/A
4.23
Bonding to ground
P
4.24
Dielectric-Liquid-Filled Equipment
Not such type of equipment
N/A
4.24.1
General
N/A