Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 67 of 75
4.16
Spacings
Line Voltage to isolated
circuit:
Thourgh air and
oversurface measured: min
6.6mm.
Live part to enclosure: min
7.2mm
P
4.17
Alternative approach to spacings
N/A
4.18
Separation of Circuits
All wires are rated for the
highest voltage
P
4.19
Overcurrent protection
N/A
4.20
Disconnecting Means
N/A
4.21
Protection of Receptacles
N/A
An output receptacle shall be protected by an overcurrent
device rated or set at not more than the rating of the receptacle
unless
(a) the circuit is not capable of delivering current in excess of
the rating of the receptacle under any conditions of loading; or
(b) electronic protection is provided that cannot be defeated by
a single fault.
N/A
4.22
Battery Supplies
No battery
N/A
4.22.1
Except as permitted by Clause 4.22.2, the batteries intended
for use with a PCE shall be supplied with the PCE.
N/A
4.22.2
Subject to the conditions specified in Clause 4.22.3, batteries
need not be supplied with a
(a) PCE that is intended to be permanently connected to the
source of supply;
(b) cord-and-plug-connected PCE having an input rating of
more than 20 A or 125 V ac and that is intended to be fastened
in place or located in a dedicated space; or
(c) a battery cabinet.
N/A
4.22.3
For PCE that are not supplied with batteries, or that contain
replaceable batteries, the instruction manual shall specify the
relevant parameters of the batteries that may be used in
accordance with Clause 5.23(e).
N/A
4.22.4
The interior of a metallic enclosure or compartment housing a
wet cell battery, such as a lead acid or nickel iron (alkaline)
storage battery, shall be protected by two coats of acid (or
alkali, as applicable) resistant paint, two coats of enamel
individually baked on, or the equivalent
N/A
4.22.5
A polymeric enclosure or compartment housing a wet cell
battery, such as a lead-acid storage battery, shall be resistant
to corrosion by acids or alkalis, as applicable.
N/A
4.22.6
The enclosure or compartment housing a wet cell battery, such
as a lead-acid storage battery, shall be constructed so that
spillage or leakage of the electrolyte from the volume of one
battery container will be contained within the enclosure and
prevented from
(a) reaching the outer surfaces of the PCE where contact with
the user is possible;
(b) contaminating adjacent electrical components or materials;
and
(c) bridging required electrical spacings.
N/A