Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 65 of 75
4.7.5
Wiring other than that of printed circuits shall consist of wire of
a type or types that are suitable for the particular application
when considered with respect to
(a) conductor size (consideration shall be given to the effects of
vibration, impact, and handling for wires smaller than No. 24
AWC);
(b) temperature and voltage to which the wiring is liable to be
subjected;
(c) exposure to oil, grease, or other substances liable to have a
deleterious effect on the insulation;
(d) exposure to moisture; and
(e) other conditions of service to which the wire is liable to be
subjected.
P
4.7.6
All wiring joints shall be provided with insulation equivalent to
that of the conductors themselves unless they are held securely
and rigidly so that the spacings required by Clause 4.16 are
maintained.
N/A
4.7.7
Cords and insulated conductors, either single or bunched, or
cabled, when passing through openings in sheet metal walls ,
shall be effectively protected by suitable bushings or well-
rounded surfaces against which the cords or conductors may
bear.
N/A
4.7.8
Conductors identified by green or the colour combination
green/yellow shall be used only for grounding or bonding
connections.
P
4.8
Electrical Insulation
P
4.8.1
Heat-resistant, moisture-absorption-resistant insulating
material, such as phenolic composition, porcelain, and cold-
moulded composition, that will withstand the most severe
conditions likely to be met in service shall be used for the
support of bare, live parts and for barriers used to obtain
required spacings (as specified in Clause 4.16), and shall
comply with the test specified in Clause 6.18.
All components are
approved and rated for
intended use
P
4.8.2
Insulating material relied on for compliance with this standard
and that can be subject to the influence of the arc formed by
the opening of a set of contacts shall be suitable for the
particular application with regards to resistance to arcing.
P
4.9
Transformers
P
4.9.1
Compliance with 22.2 CNo. 66
P
4.9.2
Extra-low voltage circuits
N/A
4.9.3
Transformer enclosure
Housed within the main
enclosureof the equipment
P
4.10
Motors
No motor
N/A
4.11
Capacitors
P
4.11.1
Capacitors shall not create a hazard when tested in accordance
with Clause 6.6.
Capacitor is part of the filter
unit and rated for intended
use
P
4.11.2
Capacitors shall not be affected adversely by the temperatures
attained by the device under the most severe conditions of
normal use.
P
4.11.3
Electrolytic or other special types of capacitors and capacitors
intended for connection directly across the line shall be made
the subject of investigation
P