Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 52 of 75
61.1.14
A cautionary marking to instruct the operator shall be visible
and legible to the operator during the intended operation of the
power unit. With reference to the Exception to 7.6.6, a marking
shall be located adjacent to the part being guarded to indicate
that the cover or guard is to be replaced before operation of the
power unit.
P
61.1.15
A warning to the serviceman that a removable panel covering a
capacitor should not be removed for whatever time - 5 minutes
maximum - is required for the capacitor to discharge to the
values specified in 9.1.6 after the power unit has been
disconnected from its source of power shall be clearly marked
on or near the panel.
N/A
61.2
General markings
P
61.2.1
A power unit shall be plainly and permanently marked where it
is readily visible - after installation in the case of a fixed power
unit - with the following:
See labels
P
a) The manufacturer's name, trade name, or trademark.
P
b) A distinctive catalog number or the equivalent.
P
c) The input and output ratings in voltage, frequency, and
amperes, watts, or volt-amperes.
P
Exception No. 1: The output ratings are not required to be
included on a unit complying with 13.1.
N/A
Exception No. 2: The output rating need not be included in a
power unit intended to charge a specific battery or battery pack
provided the unit is marked to indicate the battery or battery
pack to be used.
N/A
d) The date or other dating period of manufacture not
exceeding any three consecutive months.
See labels
P
Exception: The date of manufacture may be abbreviated; or
may be in a nationally accepted conventional code or in a code
affirmed by the manufacturer provided that the code:
N/A
1) Does not repeat in less than 20years; and
N/A
2) Does not require reference to the production records of the
manufacturer to determine when the product was
manufactured.
N/A
e) The number of phases if the product is intended for use on
a polyphase circuit. The symbol " " may be used in place of
the word "phase."
N/A
61.2.2
With respect to the frequency marking mentioned in 61.2.1:
See labels
P
a) Equipment intended to operate only from a direct-current
supply shall bear markings indicating that the supply shall be
direct current. The symbol illustrated in Figure 61.1 may be
used for this marking.
N/A
b) Equipment intended to operate only from an alternating-
current supply shall bear markings indicating that the supply
shall be alternating current. The symbol illustrated in
Figure 61.2 may be used for this marking. The markings shall
include the equipment supply-circuit frequency or supply-circuit
frequency-range rating (cycles per second, cycles/second,
hertz, c/s, cps, or Hz).
P