Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 19 of 75
d) A nonmetallic terminal cover is employed to reduce the
likelihood of bridging between terminals. The cover shall be
close-fitting over the top and all sides of the terminal block, with
no opening other than those necessary for entry of conductors.
The cover shall be attached so that it cannot be discarded. The
nonmetallic material shall comply with the requirements
in 7.1.5, and shall also comply with the requirements for
resistance to hot-wire ignition in the Standard for Polymeric
Materials - Use in Electrical Equipment Evaluations, UL 746C.
UL recognized output
connector
P
e) The power unit is marked as required by 61.1.5.
Appliance employed with
output cord
N/A
13.2
A metal enclosure of a power unit shall not be used as an
output-circuit current-carrying part.
Metal Encolsure
N/A
13.3
A power unit having a flexible power supply cord shall be
provided with an integral output cord terminating in a connector,
or with a connector directly attached to the enclosure.
P
Exception No. 1: A stationary power unit intended to be
fastened in place may be provided with output connections for
permanent wiring if the connections are enclosed but readily
accessible by means of a hinged cover, access opening, or the
equivalent. A standard trade size conduit knockout shall be
provided for connection of the output conduit system.
See 12.3.3.
N/A
Exception No. 2: This requirement does not apply to a power
unit output circuit complying with Exception No. 1 to 13.1.
N/A
13.4
The output flexible cord required by 13.3, whether permanently
attached to the power unit or provided in the form of a separate
cord set, is to be equivalent to the power supply cord specified
in Table 12.2.
SJTW
P
Exception: Output wiring for Class2 circuits may be parallel
cord insulated with rubber, neoprene, or thermoplastic having a
wall thickness not less than 0.013 inch (0.33 mm).
N/A
13.5
A battery charger provided with output contacts in a recessed
compartment to accommodate a battery or battery pack shall
either:
P
a) Employ recessed contacts that are not accessible to the
articulate probe (see Figure 8.1);
N/A
b) Employ an interlock to de-energize contacts that are
accessible to the articulate probe (see Figure 8.1) with the
battery fully removed; or
N/A
c) Have an output not exceeding60 volts dc and employ
contacts that do not provide electrical energy - high current
levels (See 6.10).
P
13.6
A special application battery charger shall be provided with a
special use polarized connector complying with the
requirements in the Standard for Component Connectors for
Use in Data, Signal, Control and Power Applications, UL 1977.
P
13.7
A connector for an output circuit, other than one intended for
use with a Class 2 circuit, shall comply with the requirements in
the Standard for Component Connectors for Use in Data,
Signal, Control and Power Applications, UL 1977, or the
Standard for Attachment Plugs and Receptacles, UL 498.
Comply with UL 1977
P
13.8
A connector intended for use with other than line voltage shall
have a nonstandard pin configuration.
Nonstandard pin connector
used