Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 73 of 75
5.21
When required by clause 4.22.13, the following marking or
equivalent shall be provided adjacent to the batteries:
CAUTION: RISK OF ELECTRIC SHOCK. BATTERY CIRCUIT
IS NOT ISOLATED FROM AC CIRCUIT. HAZARDOUS
VOLTAGE MAY EXIT BETWEEN BATTERY TERMINALS AND
GROUND. TEST BEFORE TOUCHING.
N/A
5.22
Explicit battery safety instructions (see clause 5.23) shall be
provided for a
N/A
(a) PCE having internal batteries;
N/A
(b) Remote battery supply investigated under the requirements
of this standard; and
N/A
(c) PCE intended for use with batteries to be located in a
remote battery room when the batteries are furnished with
the PCE.
N/A
Note: these instructions may appear on the PCE or in an
instruction manual accomplying thePCE.
N/A
5.23
The safety instructions for batteries that are required by clause
5.22 shall include those items on the following list. The
statement “IMPORTANT SAFETY INSTRUCTIONS” shall
precede the list. Equivalent wording of the listed instructions is
acceptable.
N/A
(a) SAVE THESE INSTRUCTIONS THIS MANUAK
CONTAINS IMPORTANT SAFETY INSTRUCTIONS;
N/A
(b) WARNING: A BATTERY CAN PRESENT A RISK OF
ELECTRICAL SHOCK, BURN FROM HIGH SHORT-
CIRCUIT CURRENT, FIRE OR EXPLOSION FROM
VENTED GASES. OBSERVE PROPER PRECAUTIONS;
N/A
(c) WHEN REPLACING BATTERIES USE THE SAME
NUMBER AND THEFOLLOWING TYPE BATTERIES;
N/A
(d) PROPER DISPOSAL OF BATTERIES IS REQUIRED.
REFER TO YOUR LOCAL CODES FOR DISPOSAL
REQUIREMENTS;
N/A
(e) The safety relevant battery parameters shall be
specified……
N/A
(f) For batteries that require the addition of water…
N/A
5.24
Multiple voltage power supplies intended for permanent
connection shall have a marking (eg, paper tag) stating the
particular voltage for which the PCE has been wired when
shipped from the factory.
N/A
5.25
When required by clause 4.20.8.2c or 4.22.14, the following
marking or equivalent shall appear adjacent to the external
battery connectors: DO NOT DISCONNECT UNDER LOAD.
N/A
5.26
The installation instructions shall include all information
(cooling, mounting, etc) necessary for the proper function of the
PCE……
N/A
5.27
When required by clause 4.19., 9.3.2.2, 10.3.1, or 13.5.2.5, the
instructions manual shall specify that overcurrent protection for
the ac output circuit is to be provided at the time of
installation……
N/A
5.28
When required by clause 4.4.2.7(b), the supply cord of a PCE
having a rating of 208V, single phase, and an attachment plug
rated at 250V shall be provided with a permanently attached
tag bearing the following or equivalent marking: CAUTION:
RISK OF ELECTRIC SHOCK AND FIRE. CONNECT TO A
RECEPTACLE WIRED FOR 208V AC.
N/A