Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 72 of 75
(2) This marking may be on a paper tag inside the equipment or
equivalent.
N/A
5.11
Notwithstanding clause 5.18.2 of CAN/CSA-C22.2 No.0, PCE
for floor mounting that do not conform wIth clause 4.2.5.5 shall
be marked with the following or equivalent statement:
DO NOT INSTALL ON OR OVER COMBUSTIBLE SURFACES
N/A
5.12
Power supplies that are intended for use in controlled
environments shall be marked with the following or equivalent:
CAUTION: FOR USE IN A CONTROLLED ENVIRONMENT.
REFER TO MANUAL FOR ENVIRONMENT CONDITIONS.
N/A
5.13
If terminals for the connection of field conductors are not
provided with the PCE, as permitted by clause 4.5.3,the
PCE……
N/A
5.14
When required by clause 4.2.6.7, the live part such as a heat
sink or relay frame shall be identified. The following or
equivalent caution shall be located on or near the live part and
shall be readily visible: CAUTION:___IS LIVE. RISK OF
ELECTRIC SHOCK. DISCONNECT POWER BEFORE
SERVICING.
N/A
Note: Space for insertion of the name of the part that is live
N/A
Note: one label may suitable to identify a number of such live
parts.
N/A
5.15
A PCE that is intended to be permanently secured to a
structure and is provided with a supply cord in accordance with
clause 4.4.1.1 shall be marked with the following or equivalent:
THE SUITABILITY OF THE USE OF FLEXIBLE CORD PER
THE CANADIAN ELECTRICAL CODE, PART I IS TO BE
DETERNINED BY THE LOCAL INSPECTION AUTHORITY
HAVING JURISDICTION.
N/A
5.16
PCE that is energized from more than one circuit shall be
permanently marked on the outside with the following or
equivalent wording:
WARNING: DISCONNECT ALL SOURCES OF SUPPLY
BEFORE SERVICING
Or
WARNING: MORE THAN ONE LIVE CIRCUIT. SEE
DIAGRAM.
……
N/A
5.17
Individual modules of a modular PCE shall be identified (eg,
recyifier/charger section, inverter section, or the equivalent) and
instructions for field assembly of each module, including an
interconnection diagram, shall be packaged with the module or
contained in the instruction manual.
N/A
5.18
When required by clause 4.22.9, the following marking or
equivalent shall appear on the cabinet or compartment housing
the batteries: WARNING: THIS CABINET (COMPARTMENT)
CONTAINS VENTED WET CELL BATTERIES. VENTILATION
OF THE ROOM IN ACCORDANCE WITH THE RULES OF
THE CANADIAN ELECTRICAL CODE, PART 1, IS
REQUIRED.
N/A
5.19
A remote battery supply/cabinet assembly shall be marked to
show the nominal dc circuit rating(volts and amperes)
N/A
5.20
When required by clause 4.23.5 b), the following marking or
equivalent shall appear on the PCE: NEUTRAL FLOATING.
N/A