Test Report
Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement – Test
Result – Remark
Verdict
Page 71 of 75
(l) For liquid-filled equipment, identification of the dielectric
liquid used and quantity in litres.
N/A
(m) For disconnect switches identification of …
N/A
(n) Where relevant for safety,the functions …
N/A
5.2
Markings shall comply with the requirements of CSA standard
CAN/CSA-C22.2 No.0
P
5.3
The polarity of the output leads shall be plainly marked unless
the PCE is provided with a polarized termination.
Polarized termination in
connector
P
5.4
Unless the proper wiring connections are plainly evident, wiring
terminals shall be marked, or the markings or installation shall
include a suitable wiring diagram to indicate the proper
connections. If additional information is necessary for the
proper use of the wiring terminals, the information shall be
provided in the installation instructions
N/A
5.5
Markings and instructions relating to conductor insulation
temperature and the temperature used for ampacity
calculations shall be in accordance with the following:
a)…
b)…
c)…
N/A
5.6
For all fuses, the required voltage and current ratings and type
of fuse shall be marked, along with the wording:
WARNING:……
N/A
5.7
When required by clause 4.12.4, the following marking or its
equivalent shall be provided: CAUTION: DISCONNECT
SUPPLY BEFORE CHANGING FUSE.
N/A
5.8
If the complete equipment consists of two or more separate
units, the specified marking shall appear on the basic unit and
each of the other units shall be marked with the name, trade
mark, or other recognized symbol of identification of the
manufacturer and the catalogue designation or equivalent. A
unit such as a plug-in assembly that is incomplete in itself and
that is not intended for separate sale shall be marked with the
name, trademark or other recognized symbol of identification of
the manufacturer, and the catalogue number or equivalent.
N/A
5.9
When required by clause 4.23.3, the equipment shall be
marked with the following or equivalent:
WARNING: BONDING BETWEEN CONDUIT CONNECTIONS
IS NOT AUTOMATIC AND MUST BE PROVIDED AS A PART
OF THE INSTALLATION or alternatively
WARNING: NONMETETALLIC EENCLOSURE DOES NOT
PROVIDE GROUNDING BETWEEN CONDUIT
CONNECTIONS. USE GROUNDING TYPE BUSHINGS AND
JUMPER WIRES.
N/A
This marking may be on a paper tag, or equivalent, inside the
equipment.
N/A
5.10
Enclosures that require hubs to be attached at the timeof
installation shall have installation information regarding the use
of suitable hubs and the location of the conduit entry.
N/A
(1) Information regarding conduit entry may include the location,
eg, the necessary flat surface clearance around a conduit
opening (see CAN/CSA-C22.2 No.0) where the wall
thickness is suitable for threading or where the requirements
in clause 4.4.1.6 apply.
N/A