Test Report

Report Reference No.: 50337286 001
CSA C22.2 No. 107.1
Clause
Requirement Test
Result Remark
Verdict
Page 63 of 75
4.2.6.7
A live heat sink for a solid-state component (eg, one mounted
on a printed circuit board), a live relay frame, and the like, that
may pose a shock or energy hazard or be mistaken for an
unenergized part shall be guarded to reduce the risk of
unintentional contact by service personnel or be marked in
accordance with Clause 5.1 4.
No Doors, Covers, and
Guards
N/A
4.2.6.8
Moving parts that can cause injury to service personnel and
must be in motion during service operations that do not invoke
the moving parts shall be so located or protected that
unintentional contact with the moving parts is not likely.
N/A
4.2.7
Special Purpose Enclosures
No Special Purpose
Enclosures
N/A
4.2.7.1
Special purpose enclosures for nonhazardous locations shall
comply with the requirements of CSA Standard CANICSA-
C22.2 No. 94.
N/A
4.2.7.2
When a supplementary housing is used to comply with Clause
4.2.7.1, the temperature rise of the enclosed equipment shall
be investigated.
N/A
4.2.8
Protection Against Corrosion Enclosures shall be protected
against corrosion as required by CSA Standard CAN/CSA-
C22.2 No. 0.
N/A
4.2.9
PCE mounting means
N/A
4.3
Mechanical Assembly
All components are secured
in place
P
4.4
Supply Connections
P
4.4.1
Permanently Connected PCE
N/A
4.4.2
Cord-Connected PCE
P
4.5
Terminal Parts and Leads
N/A
4.5.1
Terminal parts and the identification of terminal parts and leads
intended for connection to circuit conductors shall conform to
the requirements of CSA Standard CANICSA-C22.2 No. 0.
N/A
4.5.2
Field wiring terminals shall be secured to their supporting
surface by a method other than friction between surfaces so
that they will be prevented from turning or shifting in position, if
such motion may result in a reduction of spacings less than
those specified in Clause 4.16. A pressure terminal connector
need not be prevented from turning provided that no spacings
less than those required result when the terminals are turned
30" toward each other, toward uninsulated live parts of opposite
polarity, or toward grounded metal parts.
N/A