Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 57 of 75
a) An insulated grounding conductor that is identical in size,
insulation material, and thickness to the grounded and
ungrounded branch-circuit supply conductors except that it is
green with or without one or more yellow stripes is to be
installed as part of the branch circuit that supplies the unit or
system.
N/A
b) The grounding conductor described in (a) is to be grounded
to earth at the service equipment or, if supplied by a separately
derived system, at the supply transformer or motor-generator
set.
N/A
c) The attachment-plug receptacles in the vicinity of the unit or
system are all to be of a grounding type, and the grounding
conductors serving these receptacles are to be connected to
earth ground at the service equipment.
N/A
62.1.10
In accordance with the Exceptions to 12.3.1 and 12.3.7, the
instructions for a power unit intended for use with a detachable
power supply cord which is not provided with the unit shall
contain complete details concerning proper selection of the
power supply cord. The instructions shall specify selection of a
cord complying with the requirements in 12.3.1 -
12.3.5 and 12.3.10.
N/A
Exception: For a power unit intended for use in a country other
than the U.S.A., the instructions shall specify the appropriate
cord to be used (see Exception No. 4 to 12.3.1).
N/A
62.1.11
In accordance with 7.7.1 and 61.2.22, instructions for field
assembly of modules of a modular unit, including an
interconnection wiring diagram, shall be either:
N/A
a) Packaged with the modules; or
N/A
b) Contained in the instruction manual provided that the
marking on the module makes reference to the instruction
manual.
N/A
62.2
Battery chargers
P
62.2.1
A battery charger shall be provided with explicit important
safety, operation, and maintenance instructions for the user;
and, if applicable, with assembly and moving and storage
instructions.
See instruction pages
P
62.2.2
The important safety instructions and instructions for user
assembly, operation, maintenance, and moving and storage
shall be in the same manual. The important safety instructions
shall appear before the instructions for user assembly,
operation, maintenance, and moving and storage.
P
62.2.3
In an instruction manual intended for use with more than one
model or type of battery charger, the instructions applicable to
each model or type of battery charger shall be explicitly
identified.
P
Exception: This requirement does not apply to instructions that
are exactly the same for more than one model or type of battery
charger, and that could not result in confusion or
misunderstanding due to different location of controls, operating
modes, and the like.
P
62.2.4
Instructions shall be legible and shall contrast with the
background.
P