Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 54 of 75
a) The power unit is intended to be permanently connected
electrically; and
N/A
b) The input conductors and the equipment-grounding
conductor intended for such connection, with the conductor
ampacity based on125 percent of the input rating of the power
unit, would not be smaller than that specified in 61.2.12(a)
or 61.2.12(b).
N/A
Exception No. 3: In lieu of the specified marking a power unit
may be marked "CAUTION " and with the following or the
equivalent: "Risk of Fire. Do not ground the secondary circuit to
the enclosure of this power unit. "
N/A
61.2.12
The marking required by 61.2.11 shall be located at or near the
point where the equipment-grounding connection is to be
made, and shall be clearly visible both during and after
installation of the power unit as intended. The grounding
conductor size marked in the indicated space shall be:
N/A
a) Based on Column 2 of Table 17.2, using the rating of the
secondary circuit overcurrent protective device when provided;
or
N/A
b) Not less than the size of the internal wiring employed for
the output power circuits when no secondary overcurrent
protection is provided.
N/A
61.2.13
A unit having an output circuit intended to be grounded in the
field shall be marked with the following or equivalent words:
"The output circuit is considered a separately-derived source. If
local codes require grounding of this circuit, use terminal
(identify terminal) for bonding this circuit to the enclosure.
Ground the enclosure to a suitable grounding electrode in
accordance with local code requirements. "
N/A
61.2.14
A terminal in a fixed unit, as described in 20.11, intended for
connection to the grounding electrode conductor shall be
marked "Grounding Electrode Terminal."
N/A
61.2.15
In accordance with 12.2.11(a)(2), if a pressure terminal
connector is not provided with the power unit as shipped, the
power unit shall be marked to indicate which pressure terminal
connector or component terminal assembly packages are to be
used with the power unit. This marking may be provided on the
unit or on a tag attached to the unit.
N/A
61.2.16
The terminal assembly packages specified in 61.2.15 shall be
marked with an identifying marking, wire size, manufacturer's
name, and trade mark or other descriptive marking by which
the organization responsible for the product is able to be
identified.
N/A
61.2.17
If a pressure terminal connector provided with the power unit
[or in a terminal assembly as mentioned in 12.2.11(d)] for a
field installed conductor requires the use of a special tool for
securing the conductor, necessary instructions for using the
tool shall be provided. The instructions shall be included in a
readily visible location such as on the connector, on a wiring
diagram, on a tag secured to the connector or in an assembly
package provided with the power unit.
N/A
61.2.18
If Class 2 and Class 3 limited-energy circuits terminate in the
same wiring compartment, a marking shall be provided
adjacent to the wiring terminals indicating that all output circuits
are to comply with the requirements for Class 3 wiring.
Not class 2 and class 3
N/A