Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 51 of 75
61.1.7
There shall be a legible and durable marking for each
interchangeable fuse as described in 30.3, indicating the
ampere rating and the voltage rating of the fuse to be used for
replacement. The marking shall be located so that it is obvious
as to which fuse or fuseholder the marking applies. A single
marking is acceptable for a group of fuses. The marking shall
be adjacent to the fuseholder and shall consist of the word
"CAUTION " and the following or the equivalent: "For continued
protection against risk of fire, replace only with same type and
ratings of fuse. "
N/A
61.1.8
A commercial fixed power unit that exceeds the temperature
limits specified in Table 42.1 - see footnote k to Table 42.1 -
shall be legibly marked where readily visible after installation
with the word "CAUTION " and the following or the equivalent
"Hot surfaces - To prevent burns - Do not touch. "
N/A
61.1.9
A power unit provided with single-pole circuit breakers in the
input circuit in accordance with the Exception to 29.3 shall be
marked with the word "CAUTION " and the following or the
equivalent: "Risk of Electric Shock and Fire. Do not connect to
a circuit operating at more than 150 Volts to ground. "
N/A
61.1.10
A unit incorporating an overcurrent protective device in the
grounded circuit conductor as specified in Exception No. 2, item
(d) to 29.5 shall be plainly marked with the word "CAUTION "
and the following or equivalent: "Risk of Electric Shock.
Grounded circuit conductor (neutral) provided with overcurrent
protection. Test components before touching. " The marking
shall be readily visible to service personnel servicing the unit.
N/A
61.1.11
A battery charger shall be marked, where readily visible to the
user when charging batteries, with the word "CAUTION " and
the following or equivalent: "Charge only ___ type rechargeable
batteries. Other types of batteries may burst causing personal
injury and damage. "
See labels
P
Exception: A reference to a specific rechargeable battery or
battery pack for which the charger is intended may be used in
lieu of marking the type of batteries to be charged.
N/A
61.1.12
A power supply intended to be connected as described in the
Exception to 28.7 shall be marked on an inside or outside
surface or in a separate operating manual as follows:
N/A
a) A2-wire, 220 - 240-volt power unit intended for connection
to a circuit operating at 150 volts or less to ground shall be
marked with the word "DANGER " and the following or the
equivalent: "Risk of Electric Shock - Do not connect to a circuit
operating at more than 150 volts to ground. "
N/A
b) A3-wire, 3-phase, 220 - 240-volt power unit intended for
connection to a circuit operating at 150 volts or less to ground
shall be marked with the word "DANGER " and the following or
the equivalent: "To reduce the risk of electric shock - Do not
connect to a circuit operating at more than 150 volts to ground.
" The marking shall identify the leads or terminals that are to be
supplied by circuit conductors of 150 volts or less to ground.
N/A
61.1.13
A cautionary marking shall be permanent and shall be located
on a part that cannot be removed without impairing the
operation of the power unit. See 61.3.1.
Complied
P