Test Report

Report Reference No.: 50337286 001
Page 5 of 75
Summary of testing:
Model NB-58D8-5D0 was tested and fulfilled the test specifications.
The tested model was complied with the test standard UL 1012 and C22.2 No. 107.1.
The report is only evaluated the device intended to use in non- hazard location. Additional evaluation relating to
hazard location shall be considered according to National Electrical Code when fire or explosion hazards may
exist due to the accumulation of combustible dusts under abnormal operating conditions.
Particulars: test item vs. test requirements:
Equipment mobility ..................................... :
Charger
Operating condition ..................................... :
Continuous
Mass of equipment (kg) ............................... :
N/A
Test case verdicts
Test case does not apply to the test object :
N/A
Test item does meet the requirement ........ :
P(ass)
Test item does not meet the requirement .. :
F(ail)
Testing
Date of receipt of test item ......................... :
2019-12-12
Date(s) of performance of test ................... :
2019-12-12 to 2020-03-04
General remarks
The test result presented in this report relate only to the object(s) tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
1. This product is a portable Li-ion battery charger have an output other than class 2, other type battery was not
evaluated.
2. This product is provided with a detachable power supply and a polarized output connector, suitability shall
be considered in end use.
3. For indoor use only.
Electrical Rating
Model Name
Input
Output
NB-58D8-5D0
100-240Vac 50-60Hz 4A max
58.8Vdc 5A