Test Report
Report Reference No.: 50337286 001
UL 1012
Clause
Requirement – Test
Result – Remark
Verdict
Page 28 of 75
2) Is ungrounded.
N/A
20.7
With reference to 20.6, the conductor to be grounded shall be
one of the output circuit conductors.
N/A
20.8
With reference to 20.6, when the primary circuit to the
transformer is derived from the secondary of another
transformer, that circuit shall either be:
N/A
a) Grounded in accordance with 20.9 and 20.10;
N/A
b) Evaluated as being ungrounded; or
N/A
c) Ungrounded.
N/A
20.9
Grounding of the circuits specified in 20.2 - 20.8 shall be made
by a bonding jumper connected between the conductor to be
grounded and dead metal parts that are grounded via the
equipment grounding conductor.
N/A
Exception: The following provisions may be made so that the
circuit is able to be grounded in the field:
N/A
a) A field-wiring terminal intended for use with a conductor
size specified in Column4 of Table 17.2 and identified in
accordance with 12.2.12 or 12.2.13 shall be connected to the
circuit by a bonding jumper of a size not less than specified in
Column 4 of Table 17.2; and
N/A
b) A marking identifying the circuit as a separately derived
source and referencing the instruction manual in accordance
with 61.2.13.
N/A
20.10
The size of the bonding jumper specified in 20.9 shall be,
based on the current rating of the circuit, not less than the value
specified in Column 4 of Table 17.2.
Not fixed units and of units
having standard
configuration grounding
type receptacles for the
output ac power
connections.
N/A
20.11
A fixed unit shall be provided with a terminal that complies
with 12.2.3 - 12.2.9 for connection of the grounding electrode
conductor to the metal enclosure or equipment grounding
conductor described in 20.9 (a) and (b). The terminal shall be:
N/A
a) Capable of securing a conductor size, based on the
maximum current rating of the circuit, as specified in Column 3
of Table 17.2; and
N/A
b) Marked as described in 61.2.14.
N/A
20.12
For a unit having a polarized receptacle, lead, or terminal
identified as a grounded circuit (see 12.2.12 and 12.2.13) that
is not grounded at the unit itself because of an electrical
connection to supply conductors originating in another wiring
system [see 19.2(c)(1), 19.4(c), and 19.6(c)], a risk of electric
shock shall not exist between ground and the grounded circuit
contact, terminal, or lead. Compliance with this requirement
shall be determined by the test specified in 53.1.
N/A
Exception: The test described in 53.1 is not required when the
input neutral and output neutral conductors are solidly
connected together, that is, no electronic components
connected between the neutral conductors.
N/A
21
Live Parts
P
21.1
A current-carrying part shall be of silver, copper, a copper alloy,
or other material acceptable for the application.
P