Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 25 of 75
18.1
A unit rated as follows shall have the grounded conductor
connected to the components, when provided, and as specified
in 18.2 (a) - (c):
N/A
a) 120 volts, 2-wire;
N/A
b) 120/240 volts, single-phase, 3-wire;
N/A
c) 208Y/120 volts, two-phase, 3-wire;
N/A
d) 208Y/120 volts, three-phase, 4-wire;
N/A
e) 480Y/277 volts, three-phase, 4-wire in which the neutral is
used as a circuit conductor;
N/A
f) 240/120 volts, three-phase, 4-wire in which the midpoint on
one phase is used as a circuit conductor; or
N/A
g) 240 or 480 volts, three-phase, 3-wire, corner-grounded delta.
N/A
18.2
The following components, when provided, shall be connected
to the grounded conductor of a unit rated as shown in 18.1:
No such application
N/A
a) The identified terminal or lead of a receptacle as specified
in 31.8 and 31.9, as appropriate;
N/A
b) The screw shell of an Edison-base lampholder; and
N/A
c) The screw shell of an Edison-base fuseholder.
N/A
The grounded conductor of a fixed unit shall be connected to
the field-wiring terminal intended for the connection of a
grounded conductor or shall be connected to the field-wiring
lead intended for the connection of a grounded conductor. The
grounded conductor of a stationary or portable unit shall be
connected to the blade of the attachment plug intended for
connection to the grounded supply conductor. A single-pole
switch or single-pole overcurrent protective device, other than
an automatic control without a marked "off" position, shall be
connected to the ungrounded conductor. See also 28.11.
N/A
Exception: The grounded conductor may be connected to a
single-pole overcurrent protective device under the conditions
described in Exception No. 2 of 29.5.
N/A
19
Wire Bending Space
Not such construction
N/A
19.1
A permanently connected unit employing pressure terminal
connectors for field connection of circuits shall be provided with
space within the enclosure as specified in 19.3 - 19.7 for the
installation of conductors, including grounding conductors,
required by the installation.
N/A
19.2
The conductor size used in evaluating the wiring space shall be
based on the use of a conductor sized in accordance
with 12.2.2.
N/A
19.3
Wire bending space for field installed conductors shall be
provided opposite any:
N/A
a) Pressure wire connector as specified in 19.4 or 19.5; and
N/A
b) Opening or knockout for a conduit or wireway in a gutter as
specified in 19.9.
N/A
19.4
When a conductor is intended to enter or leave the enclosure
surface opposite its wire connector, the wire bending space
shall be as specified in Table 19.1. When there is an opening or
knockout for a wireway or conduit in a top, back, bottom, or
side surface, this wire bending requirement applies.
N/A
19.5
When a conductor is not intended to enter or leave the
enclosure surface opposite its wire connector, the wire bending
space shall be as specified in Table 19.2. The wire bending
space complies with Table 19.2 when:
N/A