Test Report
Report Reference No.: 50337286 001
UL 1012
Clause
Requirement – Test
Result – Remark
Verdict
Page 24 of 75
17.1.4
In addition to the parts mentioned in 17.1.3, other parts not
required to be bonded are small internal assembly screws,
rivets, or other small fasteners, a handle for a disconnect
switch, and a relay or contactor magnet and armature.
N/A
17.1.5
Uninsulated live parts and wiring shall be separated from a
moving or movable part, such as a relay or contactor armature,
a panel, or a cover by clamping, positioning, or an equivalent
means that maintains permanent separation.
P
17.1.6
An internal connection for bonding an internal part to the
enclosure may employ a quick-connect terminal of the
dimensions specified in Table 17.1 if the connector is not likely
to be displaced and the component is limited to use in a circuit
having a branch-circuit protective device rated 20 amperes or
less. A quick-connect terminal is not acceptable for a
connection to be made in the field.
No such construction
N/A
17.2
Bonding conductor
No bonding conductor
N/A
17.2.1
Bonding shall be accomplished by a metal-to-metal contact of
parts or by a separate bonding conductor as specified in 17.2.6.
No bonding conductor
N/A
17.2.2
A bonding conductor shall be copper, copper alloy, or other
acceptable material.
N/A
17.2.3
Ferrous metal in the grounding path shall be protected against
corrosion by enameling, galvanizing, plating, or other
equivalent means.
N/A
Exception: Corrosion protection is not required at electrical
connections.
N/A
17.2.4
A separate bonding conductor:
No bonding conductor
N/A
a) Shall be protected from mechanical damage or located
within the outer enclosure; and
N/A
b) Shall not be secured by a removable fastener used for a
purpose in addition to bonding unless the bonding conductor is
not likely to be omitted if the fastener is removed and replaced
as intended.
N/A
A bonding conductor shall be in metal-to-metal contact with the
parts to be bonded.
N/A
17.2.5
A splice shall not be employed in a bonding conductor.
No bonding conductor
N/A
17.2.6
A separate component-bonding conductor shall either:
No bonding conductor
N/A
a) Be not smaller than the size specified in Column 2 of
Table 17.2;
N/A
b) Be not smaller than the conductor supplying the
component; or
N/A
c) Comply with the Bonding Conductor Test, Section 56.
N/A
Exception: This requirement does not apply to component
bonding conductors complying with 17.2.7.
N/A
17.2.7
If more than one size of branch-circuit overcurrent-protective
device is used, the size of a component-bonding conductor is to
be based on the rating of an overcurrent-protective device
providing ground-fault protection for that component. For a
component individually protected by a branch circuit
overcurrent-protective device rated less than the overcurrent-
protective device used in the power unit circuit, a bonding
conductor is to be sized on the basis of the component
overcurrent-protective device rating.
N/A
18
Identification for Connection of Grounded Conductors
No such application
N/A