Test Report
Report Reference No.: 50337286 001
UL 1012
Clause
Requirement – Test
Result – Remark
Verdict
Page 22 of 75
b) To become energized through an electrical fault.
P
16.3
To determine if a part is likely to become energized, the
following factors are to be evaluated:
P
a) The proximity of wiring;
P
b) The results of a dielectric voltage-withstand test after a test
such as the overload or the endurance test; and
P
c) The results of appropriate burnout tests.
P
16.4
The grounding connection shall be located so that it is unlikely
to be removed during normal servicing. The grounding
connection shall penetrate any nonconductive coating, such as
paint or vitreous enamel, over the part to be grounded.
P
16.5
A wire-binding screw for the connection of a field-installed
equipment grounding conductor shall have a green colored
head that is either hexagonal, slotted, or both. A pressure wire
connector intended for connection of such a conductor shall be
plainly identified by:
P
a) A marking, such as "G," "GR," "GND," "Ground,"
"Grounding," or the like;
Marked
P
b) A wiring diagram attached to the power unit; or
N/A
c) The grounding symbol illustrated in Figure 16.1, on or
adjacent to the terminal.
Marked
P
The wire-binding screw or pressure wire connector shall be
located so that it does not require removal during intended
servicing of the unit.
P
16.6
The grounding terminal shall be capable of securing a
conductor of a size required for the application in accordance
with Column 2 of Table 17.2.
P
Exception: A grounding terminal capable of securing a
conductor of a size specified in 61.2.11 may be used.
N/A
16.7
A soldering lug, a screwless (push-in) connector, a quick-
connect, or other friction-fit connector shall not be used. A
sheet metal screw shall not be used to connect a grounding
conductor or connection device to an enclosure.
No such construction
N/A
Exception: A quick-connect terminal may be used in
conjunction with solder for securing the grounding conductor.
N/A
16.8
A grounding conductor shall be a size specified in Column 2 of
Table 17.2 or larger. A grounding lead shall have a free length
of at least 6 inches (152 mm), and the surface of the insulation
shall be green with or without one or more yellow stripes. No
other lead in a field-wiring compartment or visible to the
installer shall be so identified.
Intergraed within power
cord set, 18AWG. Complied
with Grounding
Connections test
P
Exception: The color coding requirement does not apply to a
Class 2 circuit when the low voltage leads or terminals are
either:
N/A
a) Located remote from the line-voltage connections and the
segregation complies with the requirements in23.1 - 23.3; or
P
b) Specifically marked so that reference to a wiring diagram is
not required.
N/A
16.9
The surface of any insulation on the grounding conductor of a
flexible supply cord shall be green with or without one or more
yellow stripes and no other conductor shall be so identified.
Complied
P