Test Report

Report Reference No.: 50337286 001
UL 1012
Clause
Requirement Test
Result Remark
Verdict
Page 16 of 75
e) After installation of the pressure terminal connector in the
intended manner, the power unit shall comply with the
requirements in this standard.
N/A
12.2.12
A terminal intended for connection of a grounded power supply
conductor shall be made of or plated with metal substantially
white in color and shall be readily distinguishable from other
terminals.
N/A
Exception: This requirement does not apply if proper
identification of that terminal is clearly shown in some other
manner, such as on an attached wiring diagram.
N/A
12.2.13
The surface of a lead for the connection of a grounded power
unit conductor shall be white or grey and shall be readily
distinguishable from the other leads.
N/A
12.3
Cord-connected power units
P
12.3.1
A portable or stationary power unit shall be provided with a
flexible cord in accordance with Table 12.2 and an attachment
plug for connection to the power supply circuit. The supply cord
shall be attached permanently to the unit or shall be in the form
of a detachable power supply cord with a means for connection
to male contacts affixed to the unit. The length of cord external
to the power unit and including the attachment plug shall not be
less than 6 feet (1.8 m) as measured from the face of the
attachment plug to the point of attachment or entry.
SJT, 18AWG x 3C. Not less
than 1.8m
P
Exception No. 1: A power unit weighing 1 pound (454 g) or less
need not comply with the cord length requirements if the total
length of the input and output cords is 6 feet (1.8 m) or more
and the length of the input cord is at least 3 feet (0.91 m).
N/A
Exception No. 2: This requirement does not apply to rack
mounted power units. See 12.3.2.
N/A
Exception No. 3: A power unit marked in accordance
with 61.2.20 and provided with instructions in accordance
with 62.1.10 need not be provided with the detachable power
supply cord.
N/A
Exception No. 4: If a power unit is intended for use in a country
other than the U.S.A., the detachable power supply cord shall
comply with the requirements of the country of destination.
N/A
12.3.2
A rack mounted power unit shall be provided with the shortest
length of flexible cord for the purpose.
Not a rack mounted power
unit
N/A
12.3.3
A stationary power unit intended to be fastened in place may
require a form of supply connection that facilitates the
interchange of equipment to maintain continuous service or
otherwise meet special conditions of use. For such service, a
Type S, SE, or equivalent flexible cord may be employed and
may be of a length appropriate for the purpose, but no longer
than 10 feet (3 m). Normally, a 24 inch (610 mm) length of cord
is sufficient for the plug and receptacle connection.
Not a stationary power unit
N/A
12.3.4
A supply cord shall be:
P
a) Of a type that is acceptable for the usage; and
SJT
P
b) Acceptable for use at a voltage and ampacity no less than
the rated voltage and ampacity of the power unit.
300V, 18AWG
P
12.3.5
The ampacity of the attachment plug for a power unit intended
to be continuously loaded for 3 hours or more shall not be less
than 125 percent of the input rating.
NEMA 5-15P
P