Test Report
Report Reference No.: 50337286 001
UL 1012
Clause
Requirement – Test
Result – Remark
Verdict
Page 13 of 75
10.2
A component such as a control switch, a lampholder, an
attachment-plug receptacle, or a plug connector shall be
mounted securely and shall be prevented from turning by
means other than friction between surfaces.
P
Exception No. 1: A switch need not comply with this
requirement if all of the following conditions are met:
N/A
a) The switch is a plunger or other type that does not tend to
rotate when operated - a toggle switch is considered to be
subject to forces that tend to turn the switch;
N/A
b) The means for mounting the switch makes it unlikely that
operation of the switch will loosen it;
N/A
c) Spacings are not reduced below the minimum acceptable
values if the switch rotates; and
N/A
d) Intended operation of the switch is by mechanical means
rather than by direct contact by persons.
N/A
Exception No. 2: A lampholder of the type in which the lamp
cannot be replaced, such as a sealed neon pilot or indicator
light, need not comply with this requirement if rotation cannot
reduce spacings below the minimum acceptable value.
N/A
10.3
A small stem-mounted device having a single-hole mounting
may be prevented from rotating by a properly applied lock
washer.
N/A
11
Protection Against Corrosion
P
11.1
Iron and steel parts shall be protected against corrosion by
enameling, painting, galvanizing, plating, or an equivalent
means.
Painted
P
Exception No. 1: This requirement does not apply to bearings,
laminations, and other parts of iron or steel such as washers
and screws.
N/A
Exception No. 2: A part need not be protected against corrosion
if the corrosion of the part does not result in a risk of fire,
electric shock, or injury to persons.
N/A
12
Supply Connections
P
12.1
Permanently-connected power units
Not permanently connected
N/A
12.1.1
A fixed power unit shall have provision for the connection of a
wiring system.
N/A
12.1.2
A knockout in a sheet-metal enclosure shall be secured and
shall be removable without undue deformation of the enclosure.
N/A
12.1.3
A knockout shall be surrounded by a flat surface to
accommodate for seating of a conduit bushing or locknut of the
appropriate size.
N/A
12.1.4
If threads for the connection of conduit are tapped all the way
through a hole in an enclosure wall, or if an equivalent
construction is employed, there shall not be less than three nor
more than five full threads in the metal, and the construction of
the device shall be such that a conduit bushing can be properly
attached.
N/A