Service Manual

Adjustment Preparation
Apply markings to the positions
of
the variable resistors
before adjustment.
If
the adjustment are out
of
the
specifidtions,
the following symptoms may occur.
[Focus gain]
If
the focus adjustment is too low the pickup lens will not
be able to focus properly and the disk will not rotate.
If
the
adjustment
is
too high portions
of
a track may be skipped
and noise will increase.
[Tracking gain]
If
the tracking adjustment
is
too low the drive
is
more
susceptable to shocks
or
bumps, portions
of
a track may be
skipped
or
the disk time counter may stop.
If
the adjustment
is
too high the pickup lens may oscillate
leading to unstable
or
distorted sound.
The
focus and tracking adjustments are done so as to
mutually satisfy conflicting characteristics.
6-3. Test equipment and tools
necessary for adjustment
I. Oscilloscope
2.
DC voltmeter
3. Non-metallic adjustment screwdriver
4.
Test
CD (A-BEC TCD-792A)
6-4. CD Drive Unit Adjustment Proce-
dure
r--------------------------,
: :
, ,
'
I
'
'
I
'
'
'
: $
~--
____
B
____________
r
____
!
IC201 ! \
€>C
401
'I
''
''
' '
I I
' '
I I
' '
' '
' '
' '
: '
'
10k
Q
FEIN
vc
10k Q
BPI.._
0
IW
Fig. 6-2
Oscilloscope
Fig. 6-3
'
r-----------------
'-------------------------------------------------------··---------------------------------------
R104 R111 R113
R118
R114
t:rn
~
L@]
I
BPij
I
F.
OFFI
FE
IN.
GND
Fig.
6-1
-9-
6-4-1.
FE
(Focus Error) bias adjustment
and focus gain adjustment
I. Connect the oscilloscope to test point
FE
IN
as
shown
in
Fig. 6-2.
2.
Turn the power switch on and set the
CD
drive to
the stop mode.
3.
Adjust
Rll4
(FE
bios) so the DC voltage at the
test point (FE IN)
is
OV.
4.
Play the first track
of
the test CD and adjust
Rill
(Focus gain) so the DC voltage is - 7mV.
6-4-2.
FE
balance and tracking gain
adjustments
I.
Connect the oscilloscope to test point
BP
IN as
shown
in
Fig. 6-3.
2.
Turn the power switch on and play the first track
of
the test CD.
3. After play has begun, connect the
TEST
pin to
GND.
4.
Adjust
RI04
(FE
balance) so the
center
voltage
of
the waveform
is
OV.
5. Adjust
Rll3
(tracking gain) so the amplitude
of
the wavefonn is 0.4V as
in
Fig. 6-4.
Fig. 6-4
-10-