User`s manual

ST-174-R2-090294
SEGA Enterprises, Ltd.
(RDJ, 7/18/94)
24
2.6 Power ON/OFF
Connecting the AC Cable
To connect the attached AC cable:
1) Make sure the power switch on the Target Box is on "OFF".
2) Insert the female end of the attached cable to the AC inlet on the Target Box.
3) Connect three terminals of AC cable to the AC outlet.
The input specification of the Target Box are as follows:
[USA]
AC85V~132V
47Hz~63Hz
Drain current: 100W(MAX)
[Europe]
AC170V~265V
47Hz~63Hz
Drain current: 100W(MAX)
Power ON
(1) After the ICE or EVA board is connected,
(a) turn on the power for the host computer (PC/AT) that is connected to
ICE or EVA board;
(b) turn on the power of the E7000 body.
(2) Turn on the power of any peripherals connected to Target Box.
(3) Turn on the power of the Target Box by pushing the power switch
upward. The built in light switch will be on when the power is on.
Caution: If the power switch is not lit up, re-check that AC cable and other cables are correctly
connected, and then turn on the power again.
If the power does not turn on, contact SEGA Technical Support Center. For more
information, refer to “Chapter 4 Support Center.”
Power OFF
Turn off the power by the reverse procedures as described above.
Caution: It may cause damage on Target Box and its peripherals if the sequence for turning
powers on is not correct.