Datasheet
SEFRAM 70
NVD - Clampmeter and Multimeter
Sefram
Sefram
Technical specifications
SEFRAM 70
DC Voltage
Range Resolution Accuracy
With batteries 7.0V to 999.9V 0.1V
±
(1.0% + 2D)
W
ithout batteries (1) 35V to 999.9V 0.1V
(1) Measurement without batteries is only available for < 35°C, > -15°C. The meter will show “bAtt” and ELV LED when measurement is not available.
M
ax. Input Current < 3.5mA @ 1000V
Overload Protection AC/DC 1000V
AC Voltage
Range Resolution Accuracy
With batteries 6.0V(1) to 999.9V 0.1V
±(1.5% + 5D)
W
ithout batteries (2) 45V to 999.9V 0.1V
(1) For > 65Hz, the minimum range is 8.0V.
(2) Measurement without batteries is only available for < 35°C, > -15°C. The meter will show “bAtt” and ELV LED when measurement is not available.
F
requency Response 45Hz to 400Hz
Max. Input Current < 3.5mA @ 1000V
O
verload Protection AC/DC 1000V
Resistor
Range Resolution Accuracy
9999Ω 1Ω
±
(1.5% + 5D)
5
0.00kΩ 0.01Ω
Output Voltage about 0.5V
O
verload Protection AC/DC 1000V
Continuity
T
he built-in buzzer sounds in the case of measuring resistance less than 1.8kΩ and may be up to 2.7kΩ.
LED RX shows at the same time.
Continuity Indicator 2.7kHz Tone Buzzer and RX LED
Response Time of Buzzer < 100 msec
Output Voltage about 0.5V
Overload Protection AC/DC 1000V
AC Ampere
Range Resolution Accuracy
200.00A 0.1A ±(3.0% + 5D)
Frequency Response 45Hz to 65Hz
O
verload Protection AC/DC 200A
Rotary Field Indication
For 3 phase 4 wire system only
Sensitivity 90V to 1000V (Phase-to-ground)
F
requency Range 45Hz to 65Hz
“
L” LED is on when the signal of L2 probe lead the signal of L1 probe; “R” LED is on when the signal of L1 probe lead the signal L2 probe.
Single-Pole Phase Check
Sensitivity 90V to 1000V (Phase-to-ground)
Frequency Range 45Hz to 65Hz
Indicator 2.7kHz Tone Buzzer and ELV LED
General Specifications
Display Count 10000 counts.
Overrange Display ”OL” or “-OL”
Conversion Rate 3 times/second
Dimensions (W x H x D) 57 x 220 x 35 mm
Weight 200g
Power Requirements AAA Size Batteryx2(R03, LR03, 24D, 24A)
Battery Life About 1000 operations. (based on Alkaline batteries, 30 sec. ON, 240 sec. OFF)
Maximum Conductor Size 16mm
IEC / EN 61010-1, IEC / EN 61010-2-032, IEC / EN 61010-2-033,
Safety Standard Compliance
IEC / EN 61010-031 for CAT IV 600V, CATIII 1000V
IEC / EN 61326-1
IEC / EN 61243-3
Pollution Degree 2
Maximum Operating Altitude 2000m (6562ft)
-15°C to 30°C, ≦80%RH
Operating Temperature & Relative Humidity
30°C to 40°C, ≦75%RH
40°C to 55°C, ≦45%RH
Storage Temperature -20 to +60°C, 0 to 80% RH (no batteries)
Temperature Coefficient 0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
IP Rating IP65
Vibration Random Vibration per MIL-PRF-28800F Class 2
Drop Protection 4 feet drop to hardwood on concrete floor.
Waranty 2 years
Supplied with: IP2X test leads, batteries, belt cover.
Optional accessories :
Test leads : SA162 :
Carrying Case : SC518 :
SA162
SC523
Probes 2mm
and 4mm
belt cover
FTSEFRAM70EN00 - Specifications can be updated without notice
For assistance and ordering
32, rue Edouard Martel - BP55- 42009 - St Etienne - cedex 2
Tél. +33 (0) 4.77.59.01.01
Fax. +33 (0) 4.77.57.23.23
Web : www.sefram.fr - e-mail : sales@sefram.fr