Specifications
Operating Manual SEFRAM 4451
M4451 A00
33
SETTLING TIME is the interval required for the pulse level to enter and remain in the specified level
ACCURACY RANGE, measured from the 90% AMPLITUDE point.
3.13 Pulse Parameter Limitations
The following formulas express the limits on Period, Width, and Delay.
Single Pulse per Period Modes
(Un-delayed, Delayed, Counted Burst with single pulse mode)
[Period - (Width + Delay)] must be > 10 ns
0.99 * Period must be > (Width + Delay)
Pulse max = 10.00 s
Pulse min = (Width + Delay + 10 ns), but not less than 20 ns
Width max = [(Period * 0.99) - Delay – 10 ns], but not more than 9.89999 s
Width min = 10 ns
Delay max = [(Period * 0.99) - Width – 10 ns], but not more than 9.89998 s
Delay min = 0
Single Pulse Transition Time Restrictions
Width must be > 1.3 * Leading Edge
(Period - Width) must be > 1.3 * Trailing Edge
Double Pulse per Period Modes
(Paired Pulse and Counted Burst with Paired pulses)
Delay must be > Width
0.99 * Delay must be > (Width + 10 ns)
Pulse max = 10.00 s
Pulse min = (Width + Delay + 10 ns), but not less than 40 ns
Width max = [(0.99 * Delay) – 10 ns], but not > 4.85000 s
Width min = 10 ns
Delay max = [(Period * 0.99) - Width –10 ns], but not > 9.80000 s
Delay min = (Width + 10 ns)
Double Pulse Transition Time Restrictions
Width must be > 1.3 * Leading Edge
(Delay - Width) must be > 1.3 * Trailing Edge
[Period - (Delay + Width)] must be > (1.3 * Trailing Edge)
Internal Trigger Burst Mode