Data Sheet
PK-1000 is based on the in-house developed clock synchronization scheduling system,
which is compatible for the aforementioned systems in both hardware and software.
But for system 3 (M tags, N anchors), to assure the measuring frequency stays at 10Hz
when all the tags are being measured, we advise you to use no more than 10 tags in the
same system. There’s no restrains on the number of anchors.
Attention:
1. The clock synchronized scheduling system is an important feature of PK-1000. The
excellent network capability of PK-1000 is owned to this feature. The positioning
accuracy in a large and complex space is 20cm.
2. There’s no restrains on the number of anchors. It means that a random tag can
communicate with any four anchors, this random tag can choose and change the anchors
it communicates with at any time.
2.1.2 Coordinates calculation
The positioning of PK-1000 refers to 2D positioning with X, Y coordinates.
2.1.2.1 Calculation theory