Data Sheet

Performance VL53L0X
28/40 DocID029104 Rev 2
5.3.2 Range profile examples
Table 13 details typical performance for the four example ranging profiles, as per
measurement conditions in Section 5.3: Ranging accuracy.
5.3.3 Ranging offset error
The table below shows how range offset may drift over distance, voltage and temperature.
Assumes offset calibrated at 10cm. See VL53L0X API User Manual for details on offset
calibration.
Table 13. Range profiles
Range profile Range timing budget Typical performance Typical application
Default mode 30 ms
1.2 m, accuracy as per
Table 12
Standard
High accuracy 200 ms 1.2 m, accuracy < +/- 3 % Precise measurement
Long range 33 ms
2 m, accuracy as per
Table 12
Long ranging, only for
dark conditions (no IR)
High speed 20 ms 1.2 m, accuracy +/- 5 %
High speed where
accuracy is not priority
Table 14. Ranging offset
Nominal
conditions
Measure point
Typical offset
from nominal
Maximum offset
from nominal
Ranging
distance
Offset calibration
at 10 cm (“zero”)
White 120 cm (indoor)
Grey 70 cm (indoor)
White 60 cm (outdoor)
Grey 40 cm (outdoor)
< 3 %
Voltage drift 2.8 V 2.6 V to 3.5 V +/- 10 mm +/- 15 mm
Temperature
drift
23 °C -20°C to +70°C +/- 10 mm +/- 30 mm