Data Sheet
Electrical characteristics VL53L0X
22/40 DocID029104 Rev 2
4 Electrical characteristics
4.1 Absolute maximum ratings
Note: Stresses above those listed in Table 6. may cause permanent damage to the device. This is
a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of the specification is not implied.
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability.
4.2 Recommended operating conditions
4.3 ESD
VL53L0X is compliant with ESD values presented inTable 8
Table 6. Absolute maximum ratings
Parameter Min. Typ. Max. Unit
AVDD -0.5 - 3.6 V
SCL, SDA, XSHUT and GPIO1 -0.5 - 3.6 V
Table 7. Recommended operating conditions
(1)
1. There are no power supply sequencing requirements. The I/Os may be high, low or floating when AVDD is
applied. The I/Os are internally failsafe with no diode connecting them to AVDD
Parameter Min. Typ. Max. Unit
Voltage (AVDD) 2.6 2.8 3.5 V
IO (IOVDD)
(2)
2. XSHUT should be high level only when AVDD is on.
Standard mode 1.6 1.8 1.9 V
2V8 mode
(3)(4)
3. SDA, SCL, XSHUT and GPIO1 high levels have to be equal to AVDD in 2V8 mode.
4. The default API mode is 1V8.
2V8 mode is programmable using device settings loaded by the API. For more details please refer to the
VL53L0X API User Manual.
2.6 2.8 3.5 V
Temperature (normal operating) -20 +70 °C
Table 8. ESD performances
Parameter Specification Conditions
Human Body Model JS-001-2012 +/- 2kV, 1500 Ohms, 100pF
Charged Device Model JZSD22-C101 +/- 500V