Data Sheet
LMV358
,
LMV321
,
LMV324
,
LMV324S
www.ti.com
SLOS263W –AUGUST 1999–REVISED OCTOBER 2014
7.7 Shutdown Characteristics, LMV324S: V
CC
+ = 2.7 V
V
CC+
= 2.7 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Supply current in shutdown mode
I
CC(SHDN)
SHDN ≤ 0.6 V 5 μA
(per channel)
t
(on)
Amplifier turn-on time A
V
= 1, R
L
= Open (measured at 50% point) 2 μs
t
(off)
Amplifier turn-off time A
V
= 1, R
L
= Open (measured at 50% point) 40 ns
(1) Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
7.8 Shutdown Characteristics, LMV324S: V
CC
+ = 5 V
V
CC+
= 5 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Supply current in shutdown mode
I
CC(SHDN)
SHDN ≤ 0.6 V, T
A
= Full Temperature Range 5 μA
(per channel)
t
(on)
Amplifier turn-on time A
V
= 1, R
L
= Open (measured at 50% point) 2 μs
t
(off)
Amplifier turn-off time A
V
= 1, R
L
= Open (measured at 50% point) 40 ns
(1) Typical values represent the likely parametric nominal values determined at the time of characterization. Typical values depend on the
application and configuration and may vary over time. Typical values are not ensured on production material.
Copyright © 1999–2014, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LMV358 LMV321 LMV324 LMV324S