User Manual

WWW. SEEEDSTUDIO.COM SEEED
e.g.:
Send “AT” command to module, and the module returns “OK”.
AT+Bxxxx
Change the serial port baud rate. The baud rate can be set to be 1,200bps, 2,400bps,
4,800bps, 9,600bps, 19,200bps, 38,400bps, 57,600bps, and 115,200bps. The default
value is 9,600bps.
e.g.: To set serial port baud rate of module to be 19,200bps, first send “AT+B19200”
command to module, and the module returns “OK+B19200”.
AT+Cxxxx
Change wireless communication channel, optional from 001 to 127 (for the wireless
channel exceeding 100, the communication distance cannot be ensured). The default
value of wireless channel is 001, and the working frequency is 433.4MHz. The
channel stepping is 400KHz, and the working frequency of Channel 100 is
473.0MHz.
e.g.:
To set the module to work at Channel 21, first send “AT+C021” command to the
module, and the module returns “COK+C021”. After exiting from the command mode,
the module will work at Channel 21, and the working frequency is 441.4MHz.
Note: As the wireless receiving sensitivity of HC-12 module is relatively high, when
the serial port baud rate is greater than 9,600bps, five adjacent channels shall be
staggered to use. When the serial port baud rate is not greater than 9,600bps, in
short-distance (within 10m) communication, also five adjacent channels shall be
staggered to use.
AT+FUx
Change serial port transparent transmission mode of module and three modes are
available, namely, FU1, FU2 and FU3. The default mode of module is FU3, and only
when serial port transparent transmission mode of two modules is set to be the same,
can normal communication be available. For detailed introduction, please see the
above “wireless serial port transparent transmission”.
e.g.:
Send “AT+FU1” to module, and the module returns “AT+0K”.
AT+Px
Set transmitting power of module, x is optional from 1 to 8, and the corresponding
transmitting power of module is as shown below:
x value 1 2 3 4 5 6 7 8
Transmitting
power of
module
(dBm)