6.6 Configure RS485 Modbus-RTU Sensor via App
Select the “Protocol as “RS485 Modbus RTU. Then set the following parameters in turn.
Baud Rate
Baud rate of communication with the sensor.
Range: 4800/9600/14400/19200/38400/57600/115200
Modbus Address
Slave address of the sensor. The range is 1 to 247.
Power Type
Periodic power: Power the sensor before data collection, and power
off the sensor after data collection. This mode reduces power
consumption and increases battery life.
Always-on: Select this mode when the sensor needs constant
power supply. Generally, an external 12V DC power supply is used.
If it is powered only by batteries, it may not work for long.
Power Voltage
Select the supply voltage to the sensor. It supports 3V/5V/12V.
Please refer to section "Power Supply Options of Sensor".
Sensor Warm-up Time
The warm-up time denotes the amount of time it takes for the
sensor to attain its highest accuracy or performance level once the
voltage supply has been applied.
Response Timeout
After Data Logger initiates a data read request to the sensor, it
waits for the timeout time for a response. If this time is exceeded,
the command will be resent; unit: 100 milliseconds.