User Guide
IoT into the Wild
32
Interface I1
The Data Logger supports two analog current signals. When the
sensor wire is connected to I1/I2, the configuration can be enabled.
Interface I2
Y= Ax + B
“Y”: It is the value Datalogger will upload.
“x”: It is the original current value.
Factory A: Custom values that can be scaled up or down by
multiples of the “x”.
Factory B: A custom value that increments or diminishes the value
of the “x”.
By setting the values of A and B, you can calculate the desired
value. If only raw values are uploaded, set A=1 and B=0.
Select the “Work Mode”.
Periodic collect mode
Periodically collect data. For example, if the uplink interval is set to
60 minutes, the data logger wakes up from the sleep state every 60
minutes, collects data, and uploads data via LoRaWAN.
Threshold mode
You can set a threshold rule for the measured value. When the rule
is triggered, the device uploads data through LoRaWAN.
Collect Interval
Data Logger is divided into uplink interval and collection interval.