Sensor Warm-up Time
The warm-up time denotes the amount of time it takes for the
sensor to attain its highest accuracy or performance level once the
voltage supply has been applied.
Digital input
Sets the type of input pulse.
Pull High: Valid when a rising edge is detected.
Pull Low: Valid when a falling edge is detected.
Digital Filter
When the pulse width exceeds 250 μs, which advised to enable it. It
is enabled by default.
Reboot to clear the
count
When a Datalogger restart occurs, the count is cleared to 0. It is
disabled by default.
Y= Ax + B
“Y”: It is the value Datalogger will upload.
“x”: It is the original counter value.
Factory A: Custom values that can be scaled up or down by
multiples of the “x”.
Factory B: A custom value that increments or diminishes the value
of the “x”.
By setting the values of A and B, you can calculate the desired
value. If only raw counter values are uploaded, set A=1 and B=0.