7. Do’s & Don’ts
Low Temperature Environment Precautions (MUST-READ
for Built-in Battery Version).
Battery normal discharge temperature range: -20 °C to 60 °C
Battery normal charging temperature range:0 °C to 45 °C
Note that if the Sensor Hub you use has a built-in lithium battery, when powered by solar energy or a DC power
adapter:
1) If the ambient temperature is below zero, the battery will stop charging and resume charging only when the
temperature is higher than 0℃.
2) While it stops charging, if the battery is exhausted, the device cannot rely on the solar power or DC power to
work. You need to wait for the ambient temperature to be higher than zero and the lithium battery is charged to a
safe use level before the device can work.
Aviation Connector Port Number (Wire Sequence)
When connecting to a custom sensor, users need to solder the aviation connector to the sensor by following the
wire number/sequence below. (contact us if you need to purchase the connector):
Plug pin
Sensor line order
Describe
1
12V
If the sensor is powered by 12v, connect this pin
2
5V
If the sensor is powered by 5v, connect this pin
3
RS485 A
-
4
RS485 B
-
5
GND
Ground