Log Analysis
The user can view the logs in the Sensor Hub’s working mode through the Sensor Hub Configuration Tool.
When abnormal activity occurs, it can be diagnosed through the log.
Enter working mode and print the hardware and software version:
<SensorHub4G-bootloader-v2.0.0 Feb 4 2021 11:09:46
Please input 'c' to enter command-line tool in 2 seconds...
<Start application
SensorHub4G 2.0.2 Mar 1 2021 19:23:12
[Flash] Flash initialize success.
Device Basic Configuration Information:
Device EUI: 2CF7F16924410088 / /Device Unique Code EUI
# App Key: 656A1B1A98EA1846037A1FA34A831572
Data interval: 5 minutes // data upload interval
Remote server: . . . / /IP domain name
Remote port: 0 / / port number
GPS Switch: N //GPS switch: N for off, Y for on, off by default
Logs Switch: Y / /Log Print: N for Off, Y for On, On by default
OTA preview: N / / Remote firmware test switch: N for off, Y for on, off by default
Sensor info OTA preview: N // Remote information test switch: N for off, Y for on, off by default
User: / / username for the server, leave blank if not applicable
Passwd: / / Password for the user server, leave blank if not applicable
Cloud platform: 1 // Data upload server: 1 for Sense CAPcloud, 2 for user server, 3 for reservation
# SenseCap platform:[0] sensecap.seeed.cn
Battery volt: 7236 mV // Built-in battery voltage
Battery: 56% // battery power
APN configuration information:
# APN: CMNET
# APN username: ***
# APN password: ***
# Cloud platform: [1] Sensecap: sensecap.seeed.cn
Hardware and software version:
# Software Version:2.0.2
# Hardware Version:3.1.0
# Boot Version:2.0.0
The application starts running
APP START RUN!
MCU reset reason: POR/PDR reset |
SensorHub-2G/4G 2.0.2 Mar 1 2021 19:23:12
[2000/01/01 00:00:03]
# Battery status[7268mv,57%,absent]
# TEMP: 24.88
# APP VER: 2.0.2
# BOOT VER: 2.0.0