Add a Custom Sensor (Example: Soil Temperature &
Moisture Sensor)
5.2.1 Preparation
Prepare the sensor: Soil Temperature & Moisture sensor, 5V, Modbus address as 128.
Solder the aviation connector to the sensor: follow the wire number/sequence, and soler the aviation connector
to the sensor .
When connecting to a custom sensor, users need to solder the aviation connector to the sensor by following the
wire number/sequence below. (contact us if you need to purchase the connector):
Aviation
Connector Pin
Sensor Wire Pin
Description
1
12V
If the sensor is powered by 12v, connect this pin
2
5V
If the sensor is powered by 5v, connect this pin
3
RS485 A
-
4
RS485 B
-
5
GND
Ground
Connect to Sensor Hub: Plug the aviation connector into any port (1 to 4) on Sensor Hub Data Logger.
5.2.2 Configure Sensors’ Basic Information
1 Read the information.