Datasheet

Datasheet [Page 16]
EMB1061
2Anti-static and high thermos tolerant tray
3Anti-static and high thermos tolerant gloves
Conditions of product storage (Storage environment is shown in figure 8):
Moisture bag must be stored in temperature below 30 and humidity less than 85%RH.
Dry packaging products, the guarantee period should be from 6 months date of packing seal.
Humidity indicator card is in the hermetic package.
Figure 8 Humidity Card
Humidity indicator card and drying situation:
2 hours drying for module if the color ring at 30%, 40%, 50% in humidity indicator card is blue
after unpacking;
4 hours drying for module if the color ring at 30% in humidity indicator card is pink after
unpacking;
6 hours drying for module if the color ring at 30%, 40% in humidity indicator card is pink after
unpacking;
12 hours drying for module if the color ring at 30%, 40%, 50% in humidity indicator card is pink
after unpacking.
Drying parameters:
Drying temperature: 125℃±5℃;
Alarm temperature: 130℃;
SMT patch when the device cool down below 36 in natural condition;
Dry times: 1;
Please dry again if the module is unsoldering in 12 hours after last drying.
SMT is unsuitable if the module packed over 3 months. There would be serious oxidation of the pad
because of immersion gold and cause false welding and lack of weld. Mxchip does not assume the