User Manual
SARK-110-ULM User’s Manual
Rev 1.0 June 22
th
, 2019 - 51 - © 2019, Melchor Varela – EA4FRB
Z0 is obtained by calculating the arithmetic mean of the real part of the following equation for all
the frequency points:
ZscZocZ =0
The calculation of the Velocity Factor (VF) and matched loss is more convoluted and will not be
explained here. The relevant information is that the VF is provided at the upper frequency and
the matched loss is provided at the maximum frequency and the arithmetic mean for all
frequency points.