4 Special Functions
4.1 Transmission Line Add/Subtract
The SARK-110-ULM provides the capability of subtracting a length of transmission line
(transpose to load) or adding a length of transmission line (transpose to input). Use the
subtraction feature to discount the effect of the feed line so the measurements will be as if the
analyzer were connected at the antenna feed point. Use the addition feature for simulating the
effect of a feed line.
The transmission line type has to be known in advance. The device provides a comprehensive
list of cable types and in addition the user can specify up to three custom cable types. The
selection of the cable is available in the «Cable Type» option of the Setup menu, see the
screenshot below:
For setting the length, select «TL LEN» option in the Function menu.
A pop-up dialog will show the coefficients of the selected cable type.
Enter the transmission line length. Use negative quantities for Subtract operations (transpose to
load) and positive quantities for Add operations (transpose to input). Notice that the length can
be changed using up and down arrow buttons when “TL LENfunction is selected.