2.4 Using the Frequency Presets
The analyzer provides predetermined frequency and span settings including the amateur radio
bands and other suitable settings. Press the Menu [ ] button to select «Preset» in the Function
menu. If «Preset» mode is already selected, press the Enter [ ] button.
Press the up or down arrow buttons to highlight the desired preset. Press the Enter [ ] button to
validate the preset selection. Press any other button to cancel the operation.
2.5 Changing the Run Status
The Run/Hold [ ] button controls the run status. The measurements can be stopped at any time
by pressing the Run/Hold [ ] button and resuming them by pressing this button again. If the Run
Mode in the Setup menu is set to «Single Shot», the sweep automatically stops on completion of
a single pass. Press the Run/Hold [ ] button to start a new sweep.
2.6 Using the Marker
The sweep modes in the SARK-110-ULM include a marker feature to display the frequency and
reading value at the marker position. The marker can either be manually positioned by the user
or set to operate in automatic tracking mode. The marker is represented by a small triangle
shape.