Data Sheet
Page 97
RFM95/96/97/98
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: sales@hoperf.com http://www.hoperf.com
WIRELESS & SENSING PRELIMINARY DATASHEET
Name
(Address)
Bits
Variable Name
Mode
Default
value
FSK/OOK Description
Service registers
7
AutoImageCalOn
rw
0x00
*
Controls the Image calibration mechanism
0 Calibration of the receiver depending on the temperature is
disabled
1 Calibration of the receiver depending on the temperature
enabled.
6 ImageCalStart wt - Triggers the IQ and RSSI calibration when set in Standby mode.
5
ImageCalRunning
r
0x00
Set to 1 while the Image and RSSI calibration are running.
Togg le s ba c k t o 0 wh en the p r o c e s s i s c o m p l e t ed
4 unused r - unused
3
Tem p C h a n g e
r
0x00
IRQ flag witnessing a temperature change exceeding
Tem p T hr e s h o l d s i n c e t h e l a s t I m a ge a n d R SSI calibration:
0 Tem p e rature ch an g e lower th a n Te m p T h re s hold
1 Temperature change greater than TempThreshold
2-1
Temp T hre s h o l d
rw
0x01
Tem perat ur e c hange thre shol d to t ri gger a ne w I/Q cali b r ation
00 5 °C
01 10 °C
10 15 °C
11 20 °C
RegImageCal
(0x3b)
0
Tem p M o n i to r O ff
rw
0x00
Controls the temperature monitor operation:
0 Temperatu re monito r i n g d o n e i n all modes exc ep t S l e e p a n d
Standby
1 Temperature monitoring stopped.
RegTemp
(0x3c)
7-0
Temp Va l u e
r
-
Measured temperature
-1°C per Lsb
Needs calibration for absolute accuracy
7-4 unused r - unused
3
LowBatOn
rw
0x00
Low Battery detector enable signal
0 LowBat detector disabled
1 LowBat detector enabled
RegLowBat
(0x3d)
2-0
LowBatTrim
rw
0x02
Trimming of the LowBat threshold:
000 1.695 V
001 1.764 V
010 1.835 V (d)
011 1.905 V
100 1.976 V
101 2.045 V
110 2.116 V
111 2.185 V
Status registers