This example is achieved by programming the Sequencer as follows:
Table 94 Beacon Mode Settings
Variable
Effect
IdleMode
1: Sleep mode
FromStart
00: To LowPowerSelection
LowPowerSelection
1: To Idle state
FromIdle
0: To Transmit state on T1 interrupt
FromTransmit
0: To LowPowerSelection on PacketSent interrupt
T
Timer1 +
T
Timer2
define the time between the start of two transmissions.