Datasheet
SH1107
52
(3) System buses Write characteristics 3 (For 4 wire SPI)
A0
CS
SCL
SI
tR
tCSS tCSH
tSAS tSAH
tSCYC
tSLW
tSHW
tSDHtSDS
tF tF
(VDD1 = 1.65 – 2.4V, TA = +25°C)
Symbol
Parameter Min.
Typ.
Max.
Unit Condition
tSCYC Serial clock cycle 500 - - ns
tSAS Address setup time 300 - - ns
tSAH Address hold time 300 - - ns
tSDS Data setup time 200 - - ns
tSDH Data hold time 200 - - ns
tCSS
CS setup time
240 - - ns
tCSH
CS
hold time time
120 - - ns
tSHW Serial clock H pulse width 200 - - ns
tSLW Serial clock L pulse width 200 - - ns
tR Rise time - - 30 ns
tF Fall time - - 30 ns
(VDD1 = 2.4 - 3.5V, TA = +25°C)
Symbol
Parameter Min.
Typ.
Max.
Unit Condition
tSCYC Serial clock cycle 250 - - ns
tSAS Address setup time 150 - - ns
tSAH Address hold time 150 - - ns
tSDS Data setup time 100 - - ns
tSDH Data hold time 100 - - ns
tCSS
CS
setup time
120 - - ns
tCSH
CS
hold time
time
60 - - ns
tSHW Serial clock H pulse width 100 - - ns
tSLW Serial clock L pulse width 100 - - ns
tR Rise time - - 15 ns
tF Fall time - - 15 ns