Datasheet
SH1107
37
16. Set VCOM Deselect Level: (Double Bytes Command)
This command is to set the common pad output voltage level at deselect stage.
n VCOM Deselect Level Mode Set: (DBH)
A0
RD
(E)
WR
(
WR/
)
D7
D6
D5
D4
D3
D2
D1
D0
0 1 0 1 1 0 1 1 0 1 1
n VCOM Deselect Level Data Set: (00H - FFH)
A0
RD
(E)
WR
(
WR/
)
D7
D6
D5
D4
D3
D2
D1
D0
0 1 0 A7
A6
A5
A4
A3
A2
A1
A0
VCOMH = β
1
X VREF = (0.430 + A [7:0] X 0.006415) X VREF
A[7:0] β
1
A[7:0] β
1
00H 0.430 20H 0.635
01H 0.436 21H 0.642
02H 0.442 22H 0.648
03H 0.449 23H 0.654
04H 0.456 24H 0.661
05H 0.462 25H 0.667
06H 0.468 26H 0.674
07H 0.475 27H 0.680
08H 0.481 28H 0.687
09H 0.488 29H 0.693
0AH 0.494 2AH 0.699
0BH 0.501 2BH 0.706
0CH 0.507 2CH 0.712
0DH 0.513 2DH 0.719
0EH 0.520 2EH 0.725
0FH 0.526 2FH 0.731
10H 0.533 30H 0.738
11H 0.539 31H 0.744
12H 0.525 32H 0.751
13H 0.552 33H 0.757
14H 0.558 34H 0.764
15H 0.565 35H 0.770 (POR)
16H 0.571 36H 0.776
17H 0.578 37H 0.783
18H 0.584 38H 0.789
19H 0.590 39H 0.796
1AH 0.596 3AH 0.802
1BH 0.603 3BH 0.808
1CH 0.610 3CH 0.815
1DH 0.616 3DH 0.821
1EH 0.622 3EH 0.828
1FH 0.629 3FH 0.834
40H - FFH 1
15.—16. Blank