Datasheet

Table Of Contents
Table 29-1. XOSC32K Sleep Behavior
CPU Mode XOSC32K.
RUNSTDBY
XOSC32K.
ONDEMAND
Sleep Behavior of XOSC32K and CFD
Active or Idle - 0 Always run
Active or Idle - 1 Run if requested by peripheral
Standby 1 0 Always run
Standby 1 1 Run if requested by peripheral
Standby 0 - Run if requested by peripheral
As a crystal oscillator usually requires a very long start-up time, the 32KHz External Crystal Oscillator will
keep running across resets when XOSC32K.ONDEMAND=0, except for power-on reset (POR). After a
reset or when waking up from a sleep mode where the XOSC32K was disabled, the XOSC32K will need
a certain amount of time to stabilize on the correct frequency. This start-up time can be configured by
changing the Oscillator Start-Up Time bit group (XOSC32K.STARTUP) in the 32 kHz External Crystal
Oscillator Control register. During the start-up time, the oscillator output is masked to ensure that no
unstable clock propagates to the digital logic.
Once the external clock or crystal oscillator is stable and ready to be used as a clock source, the
XOSC32K Ready bit in the Status register is set (STATUS.XOSC32KRDY=1). The transition of
STATUS.XOSC32KRDY from '0' to '1' generates an interrupt if the XOSC32K Ready bit in the Interrupt
Enable Set register is set (INTENSET.XOSC32KRDY=1).
The XOSC32K can be used as a source for Generic Clock Generators (GCLK) or for the Real-Time
Counter (RTC). Before enabling the GCLK or the RTC module, the corresponding oscillator output must
be enabled (XOSC32K.EN32K or XOSC32K.EN1K) in order to ensure proper operation. In the same way,
the GCLK or RTC modules must be disabled before the clock selection is changed. For details on RTC
clock configuration, refer also to 29.6.6 Real-Time Counter Clock Selection.
Related Links
14. GCLK - Generic Clock Controller
21. RTC – Real-Time Counter
29.6.3 Clock Failure Detection Operation
The Clock Failure Detector (CFD) allows the user to monitor the external clock or crystal oscillator signal
provided by the external oscillator (XOSC32K). The CFD detects failing operation of the XOSC32K clock
with reduced latency, and allows to switch to a safe clock source in case of clock failure. The user can
also switch from the safe clock back to XOSC32K in case of recovery. The safe clock is derived from the
OSCULP32K oscillator with a configurable prescaler. This allows to configure the safe clock in order to
fulfill the operative conditions of the microcontroller.
In sleep modes, CFD operation is automatically disabled when the external oscillator is not requested to
run by a peripheral. See the Sleep Behavior table above when this is the case.
The user interface registers allow to enable, disable, and configure the CFD. The Status register provides
status flags on failure and clock switch conditions. The CFD can optionally trigger an interrupt or an event
when a failure is detected.
SAM D5x/E5x Family Data Sheet
OSC32KCTRL – 32KHz Oscillators Controller
© 2019 Microchip Technology Inc.
Datasheet