20.8.2 CONFIG
20.8.3 EWCTRL
45.6.3.1 Device Temperature Measurement
9.5 NVM Software Calibration Area Mapping
The NVM Software Calibration Area contains calibration data that are determined and written during
production test. These calibration values should be read by the application software and written back to
the corresponding register.
The NVM Software Calibration Area can be read at address 0x00800080.
The NVM Software Calibration Area can not be written.
Table 9-3. NVM Software Calibration Area Mapping
Bit Position Name Description Default
Value
1:0 AC BIAS AC Comparator 0/1 Bias Scaling. To be written to
the AC CALIB register.
0x1
4:2 ADC0 BIASCOMP Bias comparator scaling. To be written to the ADC0
CALIB register.
0x7
7:5 ADC0 BIASREFBUF Bias reference buffer scaling. To be written to the
ADC0 CALIB register.
0x7
10:8 ADC0 BIASR2R Bias rail-to-rail amplifier scaling. To be written to the
ADC0 CALIB register.
0x7
15:11 Reserved - -
18:16 ADC1 BIASCOMP Bias comparator scaling. To be written to the ADC1
CALIB register.
0x7
21:19 ADC1 BIASREFBUF Bias reference buffer scaling. To be written to the
ADC1 CALIB register.
0x7
24:22 ADC1 BIASR2R Bias rail-to-rail amplifier scaling. To be written to the
ADC1 CALIB register.
0x7
35:25 Reserved - -
36:32 USB TRANSN USB TRANSN calibration value. To be written to the
USB PADCAL register.
0x09
41:37 USB TRANSP USB TRANSP calibration value. To be written to the
USB PADCAL register.
0x19
44:42 USB TRIM USB TRIM calibration value. To be written to the
USB PADCAL register.
0x6
The NVM Software Calibration Area for temperature calibration parameters can not be written.
The NVM Software Calibration Area for temperature calibration parameters can be read at address
0x00800100.
SAM D5x/E5x Family Data Sheet
Memories
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 59