Datasheet

Table Of Contents
Table 55-7. BOD33 Characteristics on V
DD
and V
BAT
Monitoring in Low-Power Mode (During
Standby/Backup/Hibernate Modes)
Symbol Parameters Conditions (see
Notes 3, 4)
Min Typ Max Unit
VBOD or VBOD-
( see Note 1)
BOD33 threshold
level Hysteresis
OFF or BOD33
threshold level
Hysteresis ON
LEVEL[7:0] = 0x00
(min)
1.39 1.510 1.62 V
LEVEL[7:0]= 0x19
(recommended
value)
1.52 1.659 1.79
LEVEL[7:0] = 0x1C
(fuse value)
1.54 1.677 1.80
LEVEL[7:0] = 0xFF
(max)
2.80 3.045 3.28
VBOD+ (see Note
2)
BOD33 threshold
level Hysteresis
ON at power
voltage rising
LEVEL[7:0] = 0x00
(min)
1.40 1.522 1.63
LEVEL[7:0]= 0x19
(recommended
value)
1.54 1.672 1.80
LEVEL[7:0] = 0x1C
(fuse value)
1.56 1.690 1.82
LEVEL[7:0] = 0xFF
(max)
2.80 3.045 3.28
Note: 
1. VBOD = VBOD- = 1.5 + LEVEL[7:0) * Level_Step LEVEL[7:0] is calibration setting bus of threshold
level.
2. VBOD+ = VBOD- + N * HYST_STEP N = 0 to 15 according to HYST[3:0] value HYST_STEP =
Level_Step.
3. Hysteresis OFF mode, HYST[3:0] = 0x0.
4. Hysteresis ON mode, HYST[3:0] = 0x1 to 0xf; Min/Typ/Max values given for 0x2.
5. At the upper side of LEVEL[7:0] values depending on the Hysteresis value chosen with HYST[3:0],
the VBOD+ level reaches an overflow, e.g., for HYST[3:0] = 0d2 the hysteresis is 2 x Level_Step =
12 mV up to position 253 and position 254 to 255 above must not be used.
SAM D5x/E5x Family Data Sheet
Electrical Characteristics at 105°C
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 2041