54.14.4 GMAC Characteristics
Timing Conditions
Table 54-59. GMAC Load Capacitance on Data, Clock Pads
Symbol Description Condition Min. Max. Units
C
L
Load
Capacitance
V
DD
=3.3V 0 20 pF
Timing Constraints
The GMAC must be constrained so as to satisfy the timings of standards given the following two tables, in
MAX corner.
Table 54-60. Minimum and Maximum Access Time of GMAC Output Signals
Symbol Parameter Min. Max. Units
GMAC
1
Setup for GMDIO
from GMDC rising
10 - ns
GMAC
2
Hold for GMDIO
from GMDC rising
10 -
GMAC
3
GMDIO toggling
from GMDC falling
0
(1)
10
(1)
Note: 
1. For GMAC output signals, min. and max. access times are defined:
The min. access time is the time between the GMDC falling edge and the signal change.
The max. access time is the time between the GMDC falling edge and the signal stabilizes.
Figure 54-17. Minimum and Maximum Access Time of GMAC Output Signals
GMDC
GMDIO
GMAC
3 max
GMAC
1
GMAC
2
GMAC
4
GMAC
5
GMAC
3 min