49.8.5 Fault Control A and B
Name:  FCTRLA, FCTRLB
Offset:  0x0C + n*0x04 [n=0..1]
Reset:  0x00000000
Property:  PAC Write-Protection, Enable-Protected
Bit 31 30 29 28 27 26 25 24
FILTERVAL[3:0]
Access
R/W R/W R/W R/W
Reset 0 0 0 0
Bit 23 22 21 20 19 18 17 16
BLANKVAL[7:0]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 15 14 13 12 11 10 9 8
BLANKPRESC CAPTURE[2:0] CHSEL[1:0] HALT[1:0]
Access
R/W R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0 0
Bit 7 6 5 4 3 2 1 0
RESTART BLANK[1:0] QUAL KEEP SRC[1:0]
Access
R/W R/W R/W R/W R/W R/W R/W
Reset 0 0 0 0 0 0 0
Bits 27:24 – FILTERVAL[3:0] Recoverable Fault n Filter Value
These bits define the filter value applied on MCEx (x=0,1) event input line. The value must be set to zero
when MCEx event is used as synchronous event.
Bits 23:16 – BLANKVAL[7:0] Recoverable Fault n Blanking Value
These bits determine the duration of the blanking of the fault input source. Activation and edge selection
of the blank filtering are done by the BLANK bits (FCTRLn.BLANK).
When enabled, the fault input source is internally disabled for BLANKVAL* prescaled GCLK_TCC periods
after the detection of the waveform edge.
Bit 15 – BLANKPRESC Recoverable Fault n Blanking Value Prescaler
This bit enables a factor 64 prescaler factor on used as base frequency of the BLANKVAL value.
Value Description
0
Blank time is BLANKVAL* prescaled GCLK_TCC.
1
Blank time is BLANKVAL* 64 * prescaled GCLK_TCC.
Bits 14:12 – CAPTURE[2:0] Recoverable Fault n Capture Action
These bits select the capture and Fault n interrupt/event conditions.
SAM D5x/E5x Family Data Sheet
TCC – Timer/Counter for Control Applications
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 1851