Datasheet

Table Of Contents
Timer/Counter for Control Application Inputs (TCC)
The TCC waveform outputs can be used as input source for the LUT. Only WO[2:0] outputs can be
selected and routed to the respective LUT input (i.e., IN0 is connected to WO0, IN1 to WO1, and IN2 to
WO2), as shown in the figure below.
Note: 
The TCC selection for each LUT follows the formula:
IN =  % C_Instance_Number
Where N represents the LUT number.
Before selecting the waveform outputs, the TCC must be configured first.
Figure 41-10. TCC Input Selection
Serial Communication Output Transmit Inputs (SERCOM)
The serial engine transmitter output from Serial Communication Interface (SERCOM TX, TXd for USART,
MOSI for SPI) can be used as input source for the LUT. The figure below shows an example for LUT0
and LUT1. The SERCOM selection for each LUT follows the formula:
IN = [ % SERCOM_Instance_Number
With N representing the LUT number and i=0,1,2 representing the LUT input index.
Before selecting the SERCOM as input source, the SERCOM must be configured first: the SERCOM TX
signal must be output on SERCOMn/pad[0], which serves as input pad to the CCL.
Figure 41-11. SERCOM Input Selection
Related Links
6. I/O Multiplexing and Considerations
32. PORT - I/O Pin Controller
14. GCLK - Generic Clock Controller
46. AC – Analog Comparators
48. TC – Timer/Counter
49. TCC – Timer/Counter for Control Applications
33. SERCOM – Serial Communication Interface
SAM D5x/E5x Family Data Sheet
CCL – Configurable Custom Logic
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 1402