Figure 41-3. Masked Input Selection
Internal Feedback Inputs (FEEDBACK)
When selected (LUTCTRLx.INSELy=FEEDBACK), the Sequential (SEQ) output is used as input for the
corresponding LUT.
The output from an internal sequential sub-module can be used as input source for the LUT, see figure
below for an example for LUT0 and LUT1. The sequential selection for each LUT follows the formula:
IN 2N = SEQ
IN 2N+1 = SEQ
With N representing the sequencer number and i=0,1,2 representing the LUT input index.
For details, refer to 41.6.2.7 Sequential Logic.
Figure 41-4. Feedback Input Selection
Linked LUT (LINK)
When selected (LUTCTRLx.INSELy=LINK), the subsequent LUT output is used as the LUT input (e.g.,
LUT2 is the input for LUT1), as shown in this figure:
SAM D5x/E5x Family Data Sheet
CCL – Configurable Custom Logic
© 2019 Microchip Technology Inc.