Datasheet

Table Of Contents
Even if the Command Inhibit (DAT) is set to 1, commands using only the CMD line can be issued if this bit
is 0.
A change from 1 to 0 rises the Command Complete (CMDC) status flag in NISTR if NISTER.CMDC is set
to 1. An interrupt is generated if NISIER.CMDC is set to 1.
If the peripheral cannot issue the command because of a command conflict error (refer to CMDCRC in
EISTR) or because of a ‘Command Not Issued By Auto CMD12’ error (refer to Section 1.2.31 “SDMMC
Auto CMD Error Status Register”), this bit remains 1 and Command Complete is not set.
Value Description
0
Can issue a command using only CMD line.
1
Cannot issue a command.
SAM D5x/E5x Family Data Sheet
SD/MMC Host Controller ...
© 2019 Microchip Technology Inc.
Datasheet
DS60001507E-page 1334